預(yù)應(yīng)力混凝土管樁偏位原因分析及補救方案
預(yù)應(yīng)力混凝土管樁偏位原因分析及補救方案
摘要:由于施工不當(dāng),在預(yù)應(yīng)力混凝土管樁應(yīng)用過程中,管樁偏位一直困擾著施工人員。通過預(yù)應(yīng)力混凝土管樁工程實例,分析了預(yù)應(yīng)力混凝土管樁偏位的原因,提出了管樁偏位的補救方案,取得了良好的實踐效果,為解決管樁偏位難題積累了經(jīng)驗。
關(guān)鍵詞: 預(yù)應(yīng)力混凝土管樁;偏位;擠土效應(yīng);補救方案;效果
Abstract: Because construction undeserved, prestressed concrete pipe pile in the application process, pipe piles for deviation has been plagued by construction workers. Through the prestressed concrete pipe pile engineering examples, this paper analyzes the prestressed concrete pipe pile of deviation of reasons and puts forward the pile of deviation of remedy, has obtained the good practical effects, to solve the deviation of pipe pile accumulated experience problem.
Keywords: prestressed concrete pipe pile;deviation; Compaction effect; Remedy; effect
隨著建筑行業(yè)的發(fā)展,建筑工程施工中不斷出現(xiàn)新技術(shù)和新工藝,預(yù)應(yīng)力混凝土管樁就是近幾年發(fā)展起來的樁基礎(chǔ)新技術(shù)。預(yù)應(yīng)力混凝土管樁具有單樁承載力性價比高、樁身成型質(zhì)量好、耐沖擊性能好、施工快捷等優(yōu)勢。但在土性復(fù)雜特別是土質(zhì)較差的軟弱地基的基坑開挖施工過程中,一旦施工措施不當(dāng),管樁極容易發(fā)生偏位,給工程留下重大隱患。所以,預(yù)應(yīng)力混凝土管樁偏位問題成為施工中急待解決的一個難題。
1 工程概況
1.1 工程簡介
某住宅小區(qū),建筑總面積約54222㎡,由8幢小高層組成,1#、8#樓,14層,建筑高度48.9m, 2#、7#樓,7層,建筑高度23.6m, 3#~6#樓,7層,建筑高度23.6m,均采用框架剪力墻結(jié)構(gòu)。
場地工程重要性等級為二級,場地復(fù)雜程度為二級地基復(fù)雜等級為二級,基坑工程安全等級為Ⅱ級。本工程選用靜壓式(PHC)預(yù)應(yīng)力混凝土管樁,樁長約20m,持力層為全風(fēng)化花崗巖,管樁安全等級為二級,柱下單樁的重要性系數(shù)為1.1,樁混凝土強度等級為C80。
其中6#樓長約34.2m,寬約11.7m,面積約400m2,共布置79根預(yù)應(yīng)力管樁,單樁豎向承載力設(shè)計值約為500kN,壓樁力約為800kN。6#樓±0.000相當(dāng)于黃海高程6.600。