建設(shè)工程基樁質(zhì)量檢測動靜對比分析
建設(shè)工程基樁質(zhì)量檢測動靜對比分析
[摘要] 我市工程樁驗收時往往采用高應(yīng)變動力檢測進行抽檢,而高應(yīng)變檢測是要建立在大量的靜載荷試驗基礎(chǔ)上進行對比總結(jié),以提高基樁高應(yīng)變動力檢測的精度。我們在近幾年的工程中,對該方法進行了分析匯總及研究,并在實際工程中推廣應(yīng)用,取得了良好的效果。本文僅列舉其中的4枚試樁動靜比對資料來反應(yīng)其高應(yīng)變檢測效果。
[關(guān)鍵詞] 基樁, 靜載試驗 ,高應(yīng)變CASE,曲線擬合法
[abstract] the our city when acceptance of engineering piles often using high strain dynamic testing sampling inspection, and high strain detection is to be built on a lot of static load test are summarized based on the contrast, in order to improve the foundation pile high strain dynamic testing precision. We in the engineering, the method of the aggregation and analysis, and the real project application and achieved good effect. This paper only lists one of the four other than static pile test data to its high strain detection effect reaction.
[key words] the foundation pile, the static load test, high strain CASE, curve-fitting
在工程樁檢測中高應(yīng)變動力檢測以其具有的簡便、快捷、經(jīng)濟等優(yōu)點,越來越多地在工程中應(yīng)用,但無論是行業(yè)標(biāo)準(zhǔn)還是地方規(guī)定均要求在可靠的動靜對比分析資料基礎(chǔ)上進行。我公司在工程檢測中時常進行高應(yīng)變與靜載荷試驗的動靜比對分析,現(xiàn)列舉其中4枚試樁進行動靜對比分析和總結(jié),完善檢測方法,提高基樁檢測水平。
http:///
一、試樁簡介
本試樁工程在中山市東區(qū)略靠近張家邊的一個工地,場地巖土層依次為雜填土(0.8~1.0m)、粘土(2.1~2.5m)淤泥質(zhì)粉質(zhì)粘土(16.2~18.5m)、粘土(5.0~
8.7m)、粉砂(1.0~1.4m)、粉質(zhì)粘土(6.8~10.7m)、含粘性土角礫(0.8~1.2m)、含礫粉質(zhì)粘土(3.2~4.9m)、強風(fēng)化熔結(jié)凝灰?guī)r(1.5~2.1m),中風(fēng)化熔結(jié)凝灰?guī)r(3.5~4.7m)、微風(fēng)化熔結(jié)凝灰?guī)r,樁端均進入中風(fēng)化熔結(jié)凝灰?guī)r。各試樁概況如下表1。